New digitally controlled MFC mass flow controller for gas, SLA5800 Biotech MassFlowControllerBROOKS INSTRUMENT
SLA585081BAB1A2S1
New digitally controlled MFC mass flow controller for gas, SLA5800 Biotech MassFlowController
BROOKS INSTRUMENT
SLA585081BAB1A2S1
Prezzo fisso più IVA
980 €
Condizione
Usato
Ubicazione
Hessisch Lichtenau 

Dati essenziali
- Descrizione macchina:
- New digitally controlled MFC mass flow controller for gas, SLA5800 Biotech MassFlowController
- Produttore:
- BROOKS INSTRUMENT
- Modello:
- SLA585081BAB1A2S1
- Condizione:
- usata
Prezzo e posizione
Prezzo fisso più IVA
980 €
- Ubicazione:
- 37235 Hessisch Lichtenau

Chiamata
Dettagli dell'offerta
- ID dell'annuncio:
- A172-08372
- numero di riferimento:
- 61764
- Aggiornamento:
- ultimo aggiornamento il 11.09.2026
Descrizione
SLA5800 Biotech - MFC - Digitally controlled mass flow controller for gas, Mass Flow Controller
elastomer-sealed mass flow controller, flow control, flow meter, flow controller, thermal mass flow
BROOKS INSTRUMENT Type SLA585081BAB1A2S1
Ser. No. 01C00500222
Year of manufacture 2020 (new / unused in original packaging)
SLA5800 Biotech series
Option package Biotech Premium Packet Code T
Mains connection 13.5 - 27 VDC (plug M8, 5 pin, male)
Power consumption max. 10 watts
PROFINET interface (2x RJ-45)
Visual display 2 LEDs (NET / MOD)
Gas connection 6 mm Swagelok
Valve design Normally closed
User gas O2 (oxygen) Active - Multiple / O2 (oxygen), N2 (nitrogen), CO2 (carbon dioxide), AIR (air)
Calibration gas N2 (nitrogen)
Flow control ranges (full scale) 20000 sccm (20 liters / minute)
Maximum inlet pressure 4500 psi (300 bar)
Normal operation Pressure differential 60 psig (4 bar)
Control range 2% to 100% of full scale (range of mechanism)
Typical accuracy from 20 to 100 % ± 0.9 % of set point for 20 to 100 % of full scale
Typical accuracy from 2 to 20 % ± 0.18 % of full scale for 2 to 20 % of full scale
Repeatability ± 0.2 % of the measured value
Resolution 0.1 % of full scale
Typical response time of the controller
Dkjdpfxeuqgbys Ab Dsw
L'annuncio è stato tradotto automaticamente e possono essersi verificati degli errori di traduzione.
elastomer-sealed mass flow controller, flow control, flow meter, flow controller, thermal mass flow
BROOKS INSTRUMENT Type SLA585081BAB1A2S1
Ser. No. 01C00500222
Year of manufacture 2020 (new / unused in original packaging)
SLA5800 Biotech series
Option package Biotech Premium Packet Code T
Mains connection 13.5 - 27 VDC (plug M8, 5 pin, male)
Power consumption max. 10 watts
PROFINET interface (2x RJ-45)
Visual display 2 LEDs (NET / MOD)
Gas connection 6 mm Swagelok
Valve design Normally closed
User gas O2 (oxygen) Active - Multiple / O2 (oxygen), N2 (nitrogen), CO2 (carbon dioxide), AIR (air)
Calibration gas N2 (nitrogen)
Flow control ranges (full scale) 20000 sccm (20 liters / minute)
Maximum inlet pressure 4500 psi (300 bar)
Normal operation Pressure differential 60 psig (4 bar)
Control range 2% to 100% of full scale (range of mechanism)
Typical accuracy from 20 to 100 % ± 0.9 % of set point for 20 to 100 % of full scale
Typical accuracy from 2 to 20 % ± 0.18 % of full scale for 2 to 20 % of full scale
Repeatability ± 0.2 % of the measured value
Resolution 0.1 % of full scale
Typical response time of the controller
Dkjdpfxeuqgbys Ab Dsw
L'annuncio è stato tradotto automaticamente e possono essersi verificati degli errori di traduzione.
Invia richiesta
Telefono & Fax
+49 5602 ... mostra
Il tuo annuncio è stato cancellato con successo
Si è verificato un errore